3 torque current reference (t current ref), Figure 6.4.3.1: torque current reference – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 148

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

20

The total speed reference value consists of the signed addition of Speed ref 1 and Speed ref 2.
Example 1:

Speed ref 1 = + 50 % Speed ref 2 = + 30 %

Speed ref = 50 % + 30 % = 80 %

Example 2:

Speed ref 1 = + 40 % Speed ref 2 = - 60 %

Speed ref = 40 % - 60 % = - 20 %

0 ... 10 V, 0 ... 20 mA and 4 ... 20 mA signals can be used when setting the reference value via terminals. The

speed reference value has an upper and a lower limit.
If the ramp is selected, (Enable ramp parameter= Enabled), the reference value input Speed ref 1 is automati-

cally linked with the ramp output.

6.4.3 Torque current reference (T current ref)

INPUT VARIABLES

T current ref

[39]

T current ref 1 [%]

[40]

T current ref 2 [%]

The current reference value is proportional to the armature current of the motor and determines the torque, the

polarity determines the torque direction. For most applications T current Ref comes from the speed regulator

output. T current ref 2 can also be used as a correction value.

To Motor Control

Torque current regulator

+

+

T

From Speed regulator

T current ref

T current lim +

136 %

T current lim -

136 %

T current ref 2

0 %

Curr limit state

Enable spd reg

T current ref 1

0 %

Figure 6.4.3.1: Torque current reference

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

T current ref 1 [%]

39

-200

+200

see 6.4.3

0

0

Speed regulator

output *

T current ref 2 [%]

40

-200

+200

0.00

0.00

*

T current ref [%]

41

-200

+200

-

-

**

* This function can be assigned to one of the freely programmable analog inputs.
** This parameter can be assigned to a freely programmable analog output.

Advertising