DV-300 Adjustable Speed Drives

——— PARAMETER LISTS ———

10

11

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

SPEED REGULAT \ Droop function

Droop gain [%]

696

Float

0.00

100.00

0.00

0.00

ü

R/W

-

-

Droop filter [ms]

697

U16

0

1000

0

0

ü

R/W

-

-

Load comp [%]

698

I16

-200

+200

0

0

ü

R/W

IA

R/W

Droop limit [FF]

700

U16

0

2*P45

1500

1500

ü

R/W

-

-

Enable droop

Enabled

Disabled

699

U16

0

1

Disabled

(0)

Disabled

(0)

ü

R/W

1

0

ID

R/W

1

0

SPEED REGULAT \ Inertia/loss cp

Inertia [kg*m*m]

1014

Float

0.001

999.999

S

S

ü

R/W

-

-

Friction [N*m]

1015

Float

0.000

99.999

S

S

ü

R/W

-

-

Torque const [N*m/A]

1013

Float

0.01

99.99

S

S

ü

R

-

-

Inertia c filter [ms]

1012

U16

0

1000

0

0

ü

R/W

-

-

CURRENT REGULAT

T current ref [%]

41

I16

-200

+200

-

-

ü

R

QA

R

Motor current [%]

199

I16

-250

250

-

-

ü

R

QA

R

Mot cur threshld [%]

1430

U16

0

200

100

100

ü

R/W

-

-

Mot cur th delay [ms]

1431

U16

0

65535

1000

1000

ü

R/W

-

-

Arm resistance [ ]

453

Float

S

S

0.500

0.500

ü

R/W

-

-

Arm inductance [mH]

454

Float

S

S

4.00

4.00

ü

R/W

-

-

E int [V]

587

I16

-80

+80

-

-

ü

R

QA

-

R&L Search

(Cur reg selftune)

OFF

ON

452

U16

0

1

OFF

OFF

ü

R/Z

0

1

-

-

Zero torque

Active

Not active

353

U16

0

1

Not active

(1)

Not active

(1)

ü

R/W

0

1

ID

L

H

R/W

FLUX REGULATION (FIELD CURRENT REGULATION)

Enable flux reg

(Enable field reg)

ON (Enabled)

OFF (Disabled)

497

U16

0

1

Enabled

Enabled

ü

R/W

1

0

ID

H

L

-

Flux reg mode

(Field reg mode)

Constant current

Voltage control

(Field weakening)

External control (OFF)

469

U16

0

2

Const.

current

(0)

Const.

current

(0)

ü

R/Z

0

1

2

-

-

Enable flux weak

(En min field cmd)

ON (Enabled)

OFF (Disabled)

498

U16

0

1

1

1

ü

R/W

1

0

ID

H

L

-

Speed-0 f weak

(Field economy)

ON (Enabled)

OFF (Disabled)

499

U16

0

1

0

0

ü

R/W

1

0

-

-

Flux reference [%]

(Field reference [%])

500

Float*

0.0

100.0

0.0

0.0

ü

R

QA

-

Flux current [%]

(Field curr %)

234

Float*

0.0

100.0

-

-

ü

R

QA

R

Out vlt level

921

Float*

0.00

100.0

100.0

100.0

ü

R/W

IA, QA

R/W