The Droop function is used when a current balancing between two drives is required. A typical situation is when

two motors are mechanically coupled and have to run at the same speed. If, because of a different characteristic

of the two speed regulators, one of the motors is driven to run at a higher speed, it will be overloaded and the

second motor will work as a brake. The Droop function permits to avoid this bad functioning by adding a com-

ponent in the in the speed reference of the drive, which is proportional to the actual load difference of the drives.

The effect is the balancing of the two motor current.
Droop gain

Droop function gain. It is defined as a percentage of the ratio between Speed base value

ant the difference Load comp - T current ref. This means that when the difference Load

comp - T current ref is 100% and Droop gain = 100%, the speed reference correction

signal is equal to Speed base value.

Droop filter

Filter time constant

Load comp

Load compensation signal. It is typically equal to the “master” drive current, but it can

also be assigned to a programmable analog output. It is defined as a percentage of Idn.

Enable droop

Enabled

Droop function enabled.

Disabled

Droop function disabled.

Droop limit

It defines the speed reference correction range in which the droop function is active.

The value to be entered is based on the factor function.

(For more detail see Figure 6.7.1 “Speed regulator”).

EXAMPLE (PIPE MILL)

M1

DRIVE

MASTER

LINE SPEED

M2

DRIVE

SLAVE

Analog

output

Analog

input

Figure 6.7.4.2: Droop function example

Example setting:

----> Pourpose: Torque of motor 1 has to be equal to torque of motor 2

Drive Master

Drive slave

Analog input 1= Speed ref 1

Analog input 1= Speed ref 1

Analog output 1= Tcurr ref

Analog input 2= Load comp

Enable droop= enables

Droop gain= 5%

Droop filter= 100ms

Droop limit=1000