2.4 SpECIFICATIONS

2.4.1 Standards

General:

EN 61800-1, EN 50178.

Climatic conditions:

IEC 68-2 part 2 and 3 (EN 60068-2-2, test Bd).

Isolations distances:

IEC 664, IEC 664 A; Environment pollution degree 2.

Interference immunity: EN 61000-4-4, Interference immunity level 4

EN 61000-4-2, Interference immunity level 6 kV CD / 8 kV AD.

Oscillation test:

EN 60068-2-6, test Fc.

EMC compatibility:

EN 68100-3, see information in “EMC Guidelines”.

Safety:

EN 50178.

Protection degree:

EN 60529.

UL approvation:

According to file No. E 61641 for approved drives series.

2.4.2 AC Input

Table 2.4.2.1: AC input votages

DC Drive series

Power section

Field circuit

Power supply regulation section

(U/V/W terminals)

(U1/V1 terminals)

(U2/V2 terminals)

230 V ±10 %*, 3Ph

6KDV3...Q2A

400 V ±10 %*, 3Ph

6KDV3...Q4E

50/60 Hz ±5 %

230 V ±10 %*, 1Ph

115 V ±15 % **, 1Ph

230 V ±10 %*, 3Ph

400 V ±10 %*, 1Ph

or

400 V ±10 %*, 3Ph

460 V ±10 %, 1Ph

230 V ±15 % **, 1Ph

440 V ±10 %, 3Ph

6KDV3...Q2B

460 V ±10 %, 3Ph

50/60 Hz ±5 %

50 / 60 Hz ±5 %

6KDV3...Q4F

480 V ±10 %, 3Ph
500 V ±10 %, 3Ph

50/60 Hz ±5 %

Gd030ge

*

With the indicated tolerance values the output voltage complies the DIN 40030 standard.

With wider tolerances the max output voltage chenges accordingly.

** To work at 115 V with drives from 224 Amps and above a jumper between terminals SA - SB

(placed on the rear size of the drive) must be inserted.