100

6.14.6 Overload control

FUNCTIONS

Overload contr

[309]

Enable overload

[318]

Overload mode

[312]

Overload current [%]

[313]

Base current [%]

[310]

Overload time [s]

[1289]

Motor ovrld preal.

[655]

Motor I2t accum

[1438]

Drive ovrld preal.

[1439]

Drive I2t accum

[311]

Pause time [s]

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Enable overload

Enabled (1) / Disabled (0)

309

0

1

Enabled

Disabled

-

Overload mode

Curr limited (0)

Curr not limited (1)

I2t Motor (2)

I2t Drive (3)

I2t Motor & Drv (4)

318

0

4

I

2

t Motor

Curr limited

-

Overload current [%]

312

P313

200

150

100

Base current [%]

313

0

P312 < 100

100

80

-

Overload time [s]

310

0

65535

60

30

-

Motor ovrld preal.

1289

0

1

-

-

Motor I2t accum

655

0,00

100,00

-

-

Drive ovrld preal.

1438

0

1

-

-

Drive I2t accum

1439

0,00

100,00

-

-

Pause time [s]

311

0

65535

540

300

-

Overld available

Overload not possible (0)

Overload possible (1)

406

0

1

-

-

Digital outp.4 *

Overload state

Current limit value (0)

Current > limit value (1)

407

0

1

-

-

*

*

This parameter can be assigned to a programmable digital output.

The Overload control function allows an overcurrent for a limited time that can also exceed the rated current of

the inverter. It is used in order to provide the drive with an increased acceleration torque or for example to allow

peak loads, such as with cyclical loads characteristis.

Enable overload

Enabled

Overload control is enabled

Disabled

Overload control is disabled

Overload mode

Curr limited

The armature current is restricted to the limits set by the Over-

load control (size and duration of overcurrent).

Curr not limited

The armature current is not limited by the Overload con-

trol. However, an alarm is possible via the Overload state

parameter. This alarm indicates whether the current is within

the set limits or not.

I2t Motor

• If Motor I2t ovrld is set to Activity = Ignore,

the current is reduced from Overload current parameter value

to Base current parameter value when Motor I2t accum =