Signal adaptation – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 258

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

130

6.15.4. Signal adaptation

SPEC FUNCTIONS

Links

Link 1

[484]

Source

[485]

Destination

[486]

Mul gain

[487]

Div gain

[488]

Input max

[489]

Input min

[490]

Input offset

[491]

Output offset

[492]

Inp absolute

Link 2 ... 6

[553] [1218] [1227] [1236] [1245] Source

[554] [1219] [1228] [1237] [1246] Destination

[555] [1220] [1229] [1238] [1247] Mul gain

[556] [1221] [1230] [1239] [1248] Div gain

[557] [1222] [1231] [1240] [1249] Input max

[558] [1223] [1232] [1241] [1250] Input min

[559] [1224] [1233] [1242] [1251] Input offset

[560] [1225] [1234] [1243] [1252] Output offset

[561] [1226] [1235] [1244] [1253] Inp absolute

Parameter description

Link 1

No.

Link 2

No.

Link 3

No.

Link 4

No.

Link 5

No.

Link 6

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Source

484

553

1218

1227

1236

1245

0

65535

0

0

-

Destination

485

554

1219

1228

1237

1246

0

65535

0

0

-

Mul gain

486

555

1220

1229

1238

1247 -10000 +10000

1

1

-

Div gain

487

556

1221

1230

1239

1248 -10000 +10000

1

1

-

Input max

488

557

1222

1231

1240

1249

-231

231-1

0

0

-

Input min

489

558

1223

1232

1241

1250

-231

231-1

0

0

-

Input offset

490

559

1224

1233

1242

1251

-231

231-1

0

0

-

Output offset

491

560

1225

1234

1243

1252

-231

231-1

0

0

-

Inp absolute

OFF / ON

492

561

1226

1235

1244

1253

0

1

OFF

OFF

-

The Link1 and Link 6 functions are two control section operating independently of each other for the signal

adaptation. With the Links, parameters can be: rectified, limited, multiplied by a factor, divided by a factor

and provided with an offset.

Source

Parameter number used as an input quantity. For example “8236” for the Ramp ref 1

parameter (44+8192 offset). Select the parameter number in the individual descriptions

or in the list of all parameters in section 10, “Parameter list”.

Destination

Parameter number, which determines the output quantity. Select the parameter number

(+8192 offset) in the individual description column or in the list of all parameters in

section 10, “Parameter lists”.

Mul gain

Multiplicative factor of the input quantity (after a possible limitation). Resolution: 5 digits.

Div gain

Divisor, through which it is possible to divide the input quantity already multiplied and

limited. Resolution: 5 digits.

Input max

Max. limit of the input quantity. Resolution: 5 digits.

Input min

Min. limit of the input quantity. Resolution: 5 digits.

Input offset

Offset to be added to the input quantity. Resolution: 5 digits.

Output offset

Offset to be added to the output quantity. Resolution: 5 digits.