DV-300 Adjustable Speed Drives

——— CONVERTER OPERATION ———

5

9

Acknowledging a failure alarm

External fault

XXXXXXXXXX

( MENU )

XXXXXXXXXX

CANC

- If a failure occurs, the appropriate failure alarm will appear in the display and the message will flash.
- Acknowledge or reset the failure by pressing the CANC key. The converter must be disabled for this and a

Start command must not be present.

Acknowledging when several failure alarms occur at the same time

External fault

Multi failures

SPEC FUNCTIONS

Failure reset

ENT

- When several failure alarms occur at the same time, the blinking message “Multi failures” will appear in the

display.

- Select the parameter Failure reset in the SPEC FUNCTIONS menu.
- Press the CANC key to acknowledge or reset the failure alarm. The converter must be disabled for this and

there should be no Start command present.

5.1.5.3 Motor potentiometer function

n

ote

!

To use the motor potentiometer function, this must be enabled with the Enable motor pot

parameter!

Acceleration, Deceleration

Motor pot

Motor pot oper

-

+

Accelerate

Decelerate

CANC

ENT

Motor pot oper

985 [rpm]

- Select the Motor pot oper parameter in the “Motor pot” submenu.
- Pressing ENT the current reference value is displayed.
- Press the + key to increase the reference value and accelerate the drive.
- Press the - key to decrease the reference value and decelerate the drive. This applies to both rotation direc-

tions.

- Press CANC to return to the “Motor pot” submenu.