Selection from predefined values, Autotuning of analog input – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual
Page 80
GEI-100332Ga
——— CONVERTER OPERATION ———
5
4
Selection from predefined values
ENT
FLUX REGULATION
Flux reg mode
-/+
Flux reg mode
-/+
Field weakening
CANC
ENT
Flux reg mode
-/+
Constant current
Flux reg mode
-/+
OFF
+
+
-
-
ok
Return without changes
CANC
ENT
ok
CANC
ENT
ok
Return without changes
Return without changes
- The parameters that can be selected among the several possiblities are marked with -/+ on the keypad dis-
play.
- To change a value press ENT. The current value is shown in the display. This can be changed with the +
and - keys.
- Confirm the new value and return to the previous display by pressing ENT.
- Return without changes via CANC
Autotuning of Analog input
ENT
Analog input 1
Auto tune inp 1
Auto tune inp 1
Tuning
Auto tune inp 1
Ready
- Select the parameter Auto tune input XX.
- Press ENT
- The tuning procedure will run automatically. The messages “Tuning” and “Ready” will appear in succession
before the original parameter is shown.
n
ote
!
The maximum signal possible must be present on the analog input concerned during the
tuning procedure.