GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 397

Advertising
background image

DV-300 Adjustable Speed Drives

——— PARAMETER LISTS ———

10

3

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

Drive ready

Drive ready

Drive not ready

380

U16

0

1

-

-

-

R

1

0

QD

H

L

R

1

0

Quick stop

Quick stop

No Quick stop

343

U16

0

1

No Quick

stop

No Quick

stop

-

R/W

0

1

-

-

Start/Stop

Start

Stop

315

U16

0

1

Stop

(0)

Stop

(0)

R/W

1

0

13

H

L

R/W

1

0

Fast stop

Fast Stop

No Fast Stop

316

U16

0

1

No Fast

Stop

No Fast

Stop

-

R/W

0

1

14

L

H

R/W

0

1

DRIVE STATUS

Ramp ref 1 [FF]

44

I16

-2 P45 +2 P45

0

0

ü

R/W

IA, QA

R/W

Enable drive

Enabled

Disabled

314

U16

0

1

Disabled

Disabled

ü

R/W

1

0

12

H

L

R/W

1

0

Start/Stop

Start

Stop

315

U16

0

1

Stop

(0)

Stop

(0)

ü

R/W

1

0

13

H

L

R/W

1

0

Output voltage [V]

233

Float **

0

999

-

-

ü

R

QA

R

Motor current [%]

199

I16

-250

250

-

-

ü

R

QA

R

Actual spd (rpm)

122

I16

-8192

+8192

-

-

ü

R

QA

R

Speed ref (rpm)

118

I16

-32768

+32767

-

-

ü

R

QA

R

Output power [kW]

1052

Float

0.01

9999.99

-

-

ü

R

-

-

Flux current (A)

(Field curr amps (A))

351

Float

0.1

99.9

S

S

ü

R

-

-

Mains voltage [V]

466

U16

0

999

-

-

ü

R

-

-

Digital I/Q

-

-

ü

-

-

-

START UP

Speed base value [FF]

45

U32***

1

16383

1500

1500

ü

R/Z

-

R

Nom flux curr [A]

(Field curr scale [A])

374

Float

0.5

70.0

S

S

ü

R/Z

-

-

Speed-0 f weak

(Field economy)

ON (Enabled)

OFF (Disabled)

499

U16

0

1

0

0

ü

R/W

1

0

-

-

Acc delta speed [FF]

21

U32

0

232-1

100

100

ü

R/W

-

-

Acc delta time [s]

22

U16

0

65535

1

1

ü

R/W

-

-

Dec delta speed [FF]

29

U32

0

232-1

100

100

ü

R/W

-

-

Dec delta time [s]

30

U16

0

65535

1

1

ü

R/W

-

-

START UP \ Motor data

Motor nom flux

(Motor field curr [A])

280

Float

0.0

P374

P374

P374

ü

R/Z

-

-

Flux reg mode

(Field reg mode)

Constant current

Voltage control

(Field weakening)

External control (OFF)

469

U16

0

2

Const.

current

0

Const.

current

0

ü

R/Z

0

1

2

-

-

Full load curr [A]

179

Float

0.1

IdAN

IdAN

IdAN

ü

R/Z

-

-

Motor max speed [rpm]

162

Float *

0

6553

1500

1500

ü

R/Z

-

R

Max out voltage [V]

175

Float

20

999

400

400

ü

R/Z

-

-

Flux weak speed [%]

(Crossover speed [%])

456

U16

0

100

100

100

ü

R/Z

-

R

Advertising