4 multi ramp function – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 222

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

94

6.14.4 Multi ramp function

FUNCTIONS

Multi ramp fct

[243]

Enab multi rmp

[202]

Ramp selector

Multi ramp fct

Ramp 0

Acceleration 0

[659]

Acc delta speed0 [FF]

[660]

Acc delta time 0 [s]

[665]

S acc t const 0 [ms]

Deceleration 0

[661]

Dec delta speed0 [FF]

[662]

Dec delta time 0 [s]

[666]

S dec t const 0 [ms]

Ramp 1

Acceleration 1

[23]

Acc delta speed1 [FF]

[24]

Acc delta time 1 [s]

[667]

S acc t const 1 [ms]

Deceleration 1

[31]

Dec delta speed1 [FF]

[32]

Dec delta time 1 [s]

[668]

S dec t const 1 [ms]

Ramp 2

Acceleration 2

[25]

Acc delta speed2 [FF]

[26]

Acc delta time 2 [s]

[669]

S acc t const 2 [ms]

Deceleration 2

[33]

Dec delta speed2 [FF]

[34]

Dec delta time 2 [s]

[670]

S dec t const 2 [ms]

Ramp 3

Acceleration 3

[27]

Acc delta speed3 [FF]

[28]

Acc delta time 3 [s]

[671]

S acc t const 3 [ms]

Deceleration 3

[35]

Dec delta speed3 [FF]

[36]

Dec delta time 3 [s]

[672]

S dec t const 3 [ms]

The Multi ramp function enables up to four different ramps to be called up. The acceleration and deceleration

times can also be defined here separately. The ramps are called up via digital signals.

Advertising