storm-control [arp|broadcast|multicast|unicast] level <1-1000000> [fe <1-4>|

ge <1-8>|port-channel <1-8>|up1|wlan <WLAN-NAME>]

storm-control [arp|bcast|multicast|unicast] log

[<0-7>|alerts|critical|debugging|

emergencies|errors|informational|none|notifications|warnings]

Example

rfs7000-37FABE(config-fw-policy-test)#storm-control arp log warning

rfs7000-37FABE(config-fw-policy-test)#storm-control broadcast level 20000 ge 4

rfs7000-37FABE(config-fw-policy-test)#show context

firewall-policy test

ip dos fraggle drop-only

no ip dos tcp-sequence-past-window

ip dos tcp-max-incomplete high 600

arp

Configures storm control for ARP packets

broadcast

Configures storm control for broadcast packets

multicast

Configures storm control for multicast packets

unicast

Configures storm control for unicast packets

level <1-1000000>

Configures the allowed number of packets received per second before storm control begins

<1-1000000> – Sets the number of packets received per second

fe <1-4>

Sets the FastEthernet port for storm control from 1 - 4

ge <1-8>

Sets the GigabitEthernet port for storm control from 1 - 8

port-channel <1-8>

Sets the port channel for storm control from 1- 8

up1

Sets the uplink interface

wlan <WLAN-NAME>

Configures the WLAN

<WLAN-NAME> – Sets the WLAN ID for the storm control configuration

arp

Configures storm control for ARP packets

broadcast

Configures storm control for broadcast packets

multicast

Configures storm control for multicast packets

unicast

Configures storm control for unicast packets

log

Configures the storm control log level for storm control events

<0-7>

Sets the numeric logging level from 0 - 7

alerts

Numerical severity 1. Indicates a condition where immediate action is required

critical

Numerical severity 2. Indicates a critical condition

debugging

Numerical severity 7. Debugging messages

emergencies

Numerical severity 0. System is unusable

errors

Numerical severity 3. Indicates an error condition

informational

Numerical severity 6. Indicates a informational condition

none

Disables storm control logging

notification

Numerical severity 5. Indicates a normal but significant condition

warnings

Numerical severity 4. Indicates a warning condition. This is the default setting.