Publication 900-UM007D-EN-E - January 2011

Parameter Adjustments & Application Considerations

4-71

1. Press the O key for at least 3 seconds to move from the Operation

function group to the Initial Setting function group.

Figure 4.153

2. Select the Program Pattern parameter by pressing the M key.

Figure 4.154

3. Use the U key to set the parameter to STOP.

Figure 4.155

4. Press the O key for at least 1 second to move from the Initial Setting

function group to the Operation function group.

Figure 4.156

5. Press the O key to move from the Operation function group to the

Adjustment function group.

Figure 4.157

6. Select the Soak Time parameter by pressing the M key.

Figure 4.158

in-t

5

Input type

ptrn

off

Program Pattern

ptrn

stop

C

25

100

PV/SP

l.adj

Adjustment
function group
display

soak

1

Soak time