Temperature units (° c/ ° f) selection – Rockwell Automation 900-TC32 Digital Temperature Controllers, Series B User Manual
Page 281

Publication 900-UM007D-EN-E - January 2011
Parameter Functions & Definitions
5-53
Related Parameter
• Input Type (Initial Setting function group, page 5-50)
Temperature Units
(°C/°F) Selection
Conditions of Use:
The Input Type must be configured for a temperature
input (RTD, non-contact, or thermocouple).
Function:
This parameter allows you to configure the temperature input units
to either
°C or °F.
Related Parameter
• Input Type (Initial Setting function group, page 5-50)
Table 5.BG Decimal Point
Parameter
Controller Type
Configurable Range
Default
Decimal Point Controllers with
Thermocouple/Resistance
Thermometer (RTD) inputs
0…1
0
Controllers with Analog Inputs
0…3
0
Table 5.BH
Configured Value Meaning
Example
0
0 digits to the right of the decimal point
1234
1
1 digits to the right of the decimal point
123.4
2
2 digits to the right of the decimal point
12.34
3
3 digits to the right of the decimal point
1.234
Table 5.BI
Selections
Default Units
c: °C
f: °F
c
d-u