Rockwell Automation 900-TC32 Digital Temperature Controllers, Series B User Manual

Page 368

Advertising
background image

Publication 900-UM007D-EN-E - January 2011

B-8

➍ Initialized when the transfer output type is changed.

Initialized if the Input Type, temperature unit, scaling upper/Lower-Limit, or SP upper/Lower-Limit is changed
when the transfer output type is SP, ramp SP, or PV.
(When initialized by the initializing settings, it is initialized to 100.0/0.0.)

➎ When the Manual MV Limit Enable parameter is configured to ON, the setting range will be the MV lower limit

to the MV upper limit

Extraction of Square
Root Enable

sqr

OFF, ON

off

on

OFF

None

Move to Advanced
Setting function group

amov

−1999…9,999

0

None

➊Set “None” as the unit for analog inputs

➋Initial Setting function group

➌PRST (Program Start) can be configured even when the Program Pattern parameter is configured to OFF, but the function will be disabled.

Table B.C — Initial Setting Function Group

Parameters

Characters

Setting (Monitor) Value

Display

Default

Unit

Set Value

Table B.D

Transfer Output Type

Setting (Monitor) Range

Default (Transfer Output
Upper/Lower-Limits)

Unit

Set Point

SP Lower-Limit to SP Upper-Limit

SP Upper-Limit/Lower-Limit

EU

Set Point During SP Ramp

SP Lower-Limit to SP Upper-Limit

SP Upper-Limit/Lower-Limit

EU

PV

Temperature: Sensor setting range Lower-Limit
to sensor setting range Upper-Limit

Input setting range upper/Lower-Limit

EU

Analog: Scaling Lower-Limit to scaling
Upper-Limit

Scaling upper/Lower-Limit

EU

MV Monitor (Heating)

Standard:

−5.0…105.0

Heating/cooling: 0.0…105.0

100.0/0.0

%

MV Monitor (Cooling)

0.0…105.0

100.0/0.0

%

Table B.E — Manual Control Function Group

Parameters

Characters

Setting (Monitor) Value

Display

Default

Unit

Set Value

Manual MV

−5.0…105.0 (standard)

−105.0…105.0 (heating/cooling)

0.0

%