Enappa, Appendix, Specifications – Rockwell Automation 900-TC32 Digital Temperature Controllers, Series B User Manual

Page 351

Advertising
background image

A-1

Publication 900-UM007D-EN-E - January 2011

Appendix

A

Specifications

For the setting ranges for each sensor input, refer to page A-9.

Available from Little Fuse or Bussmann (part no. GDC-2A).

For the setting ranges for each sensor input, refer to page A-9.

Always connect an AC load to a Triac output. The output will not turn OFF if a DC load is connected.

Table A.A

Technical/Control

Supply Voltage

100…240V AC, 50/60 Hz

24V AC, 50/60 Hz/24V DC

Operating Voltage Range

85 to 110% of rated supply voltage

Power Consumption

900-TC16

7.5 VA

5 VA/3 W

900-TC8

10 VA

5.5 VA/4 W

900-TC32

5.5 VA

3 VA/2W

Recommended line fuse

Type: T2A, 250V AC, time lag, low shut-off capacity

Sensor Input

Sensor Input

Temperature Input Type
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PL II
Platinum resistance thermometer: Pt100, JPt100
Infrared temperature sensor: 10…70

°C, 60…120°C, 115…165°C, 140…260°C

Millivolt input: 0 to 50 mV

Supported by 900-TC8 & 900-TC16: Controllers with Analog Inputs
Current input: 4…20 mA, 0…20 mA (Input impedance: 150

Ω max.)

Voltage input: 1…5V, 0…5V, 0…10V (Input impedance: 1 M

Ω max.)

Control Output

Relay Output 900-TC16

Relay output:
SPST-NO, 250V AC, 3 A (resistive load), electrical durability: 100,000
operations
Min. applicable load: 5V, 10 mA

Triac (AC) output
SPST-NO, 250V AC, 3 A (resistive load), electrical durability: 1,000,000
operations
Load power supply voltage: 75…250V AC

Leakage current: 5 mA max. (250V AC, 60 Hz)

900-TC8

Relay output:
SPST-NO, 250V AC, 5 A (resistive load), electrical durability: 100,000
operations
Min. applicable load: 5V, 10 mA

Triac (AC) output:
SPST-NO, 250V AC, 3 A (resistive load), electrical durability: 1,000,000
operations
Load power supply voltage: 75…250V AC
Leakage current: 5 mA max. (250V AC, 60 Hz)

900-TC32

Relay output:
SPST-NO, 250V AC, 2 A (resistive load), electrical durability: 100,000
operations
Min. applicable load: 5V, 10 mA

Advertising