Publication 900-UM007D-EN-E - January 2011

B-7

Table B.C — Initial Setting Function Group

Parameters

Characters

Setting (Monitor) Value

Display

Default

Unit

Set Value

Alarm 2 Type

alt2

Same settings as the alarm 1 type.

NOTE: The 12: LBA (Loop Burnout
Alarm) setting cannot be used.

2

None

Alarm 2 Hysteresis

alh2

Universal input: 0.1…999.9

0.2

°C or °F ➊

Analog input: 0.01…99.99

0.02

%FS

Alarm 3 Type

alt3

Same settings as the alarm 2 type

2

None

Alarm 3 Hysteresis

alh3

Universal input: 0.1…999.9

0.2

°C or °F ➊

Analog input: 0.01…99.99

0.02

%FS

Transfer output type

tr-t

OFF:OFF
SP:Set point
SP-M:Ramp set point
PV:Process value
MV:Manipulated variable (heating)
C-MV:Manipulated variable (cooling)

off

sp

sp-m

pv

mv

c-mv

OFF

None

Transfer Output
Upper-Limit

tr-h

Transfer Output
Lower-Limit

tr-l

Linear Current Output

o1-t

4-20: 4…20 mA
0-20: 0…20 mA

4-20

0-20

4-20

None

Number of Multi-SP
Uses

ev-m

0…2

1

None

Event Input
Assignment 1

ev-1

NONE: None
STOP:

RUN/STOP

MANU: Auto/manual switch
PRST:

Program start

DRS: Invert Direct/Reverse Operation
AT-2: 100% AT Execute/Cancel
AT-1: 40% AT Execute/Cancel
WTPT: Setting Change Enable/Disable
LAT: Alarm Latch Cancel

none

stop

manu

prst

drs

at-2

at-1

wtpt

lat

NONE

None

Event Input
Assignment 2

ev-2

NONE: None
STOP:

RUN/STOP

MANU: Auto/manual switch
PRST:

Program start

DRS: Invert Direct/Reverse Operation
AT-2: 100% AT Execute/Cancel
AT-1: 40% AT Execute/Cancel
WTPT: Setting Change Enable/Disable
LAT: Alarm Latch Cancel

none

stop

manu

prst

drs

at-2

at-1

wtpt

lat

STOP

None