Registering calibration data, A 20, 1v 5 – Rockwell Automation 900-TC32 Digital Temperature Controllers, Series B User Manual

Page 381: 2v10, 1v 1, 2v 1

Advertising
background image

Publication 900-UM007D-EN-E - January 2011

Calibration

C-3

Controllers with Analog Inputs (900-TC8 & 900-TC16)

Figure C.2

When calibration has been performed after purchase, the user calibration
information shown in the following illustration will be displayed when moving
to the calibration level.

Figure C.3

Registering Calibration
Data

The new calibration data for each item is temporarily registered. It can be
officially registered as calibration data only when all items have been calibrated
to new values. Therefore, be sure to temporarily register all items when you
perform the calibration. When the data is registered, it is also recorded that
user calibration has been performed.

4: 0 to 10 V

2: 1 to 5 V
3: 0 to 5 V

0: 4 to 20 mA
1: 0 to 20 mA

adj

30

a 20

c8e7

str

no

1v 5

c7c3

2v10

b104

a 1

4677

1v 1

sac0

2v 1

4ad9

Advanced Setting

Function Group

Current Input

Current Input

Voltage Input

Moves automatically according to input type.

.adj

30

A Dot is Displayed