Monitor/setting item level, Press the o key for at least 1 s – Rockwell Automation 900-TC32 Digital Temperature Controllers, Series B User Manual

Page 378

Advertising
background image

Publication 900-UM007D-EN-E - January 2011

B-18

M

M

M

M

M

M

a1lt

off

a2lt

off

a3lt

off

prlt

3

sero

off

cjc

on

rlrv

M

M

off

colr

red

pv-b

5.0

M

M

M

M

M

M

M

M

M

hsu

on

hsl

off

hsh

0.1

lba

0

lbal

8.0

lbab

3.0

out1

o

out2

none

M

init

off

M

M

M

M

M

M

M

M

mspu

off

spru

m

rest

a

sb1n

n-o

sb2n

n-o

sb3n

n-o

hbu

on

hbl

off

hbh

0.1

M

M

M

M

ra1m

0

ra2m

0

ra2

0

ra1

0

rac

0

M

M

M

M

pf

a-m

pfd1

1

pfd2

0

pfd3

0

M

M

M

M

M

spdp

4

odsl

o

pvdp

on

pvst

off

svst

off

M

M

pfd4

0

pfd5

0

M

M

cmov

0

inf

0.0

M

M

alfa

0.65

st-b

15.0

M

M

at-h

0.8

at-g

0.8

M

lcma

20.0

M

M

M

M

M

M

a1on

0

a2on

0

a3on

0

a1of

0

a2of

0

a3of

0

M

M

M

M

M

ocu

on

ocl

off

och

0.1

M

M

M

M

M

sub1

alm1

sub2

alm2

csel

on

t-u

m

alsp

sp-m

M

sub3

alm3

M

pvrp

4

csca

off

M

manl

off

M

M

M

pvad

off

o-dp

off

ret

off

M

istp

ins1

M

M

mvse

off

amad

off

rt

off

M

RT

M

25

0

PF

PF

PF

PF

Monitor/Setting Item Level

M

M

M

M

M

M

alt2

2

alt3

2

tr-t

off

tr-h

100.0

tr-l

0.0

amov

0

M

o1-t

4-20

M

sqr

off

M

M

M

ev-m

1

ev-1

none

ev-2

stop

alh3

0.2

M

alh2

0.2

M

d.ref

0.25

(900-TC8 and 900-TC16 only)

C

Monitor/Setting
Item Display 1

Note:

The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to 5 parameters (advanced setting function group).

Monitor/Setting
Item Display 2

Monitor/Setting
Item Display 3

Monitor/Setting
Item Display 4

Monitor/Setting
Item Display 5

Press the

O

Key for at least 1 s.

Advanced Setting Function Group

C

Alarm 2 Type

Alarm 3 Type

Alarm 2

Hysteresis

Alarm 3

Hysteresis

C

Transfer Output Type

Linear output

Transfer Output
Upper Limit

Transfer Output
Lower Limit

Linear Current Output

Linear output

Number of Multi-SP Uses
Two SPs: 1
Four SPs: 2

Event Input
Assignment 1

Event Input
Assignment 2

Extraction of Square
Root Enable

Move to Advanced Setting
Function Group
Displayed when initial set-
ting/communications pro-
tect is set to 0.

Move by setting password (

169).

Parameter Initialization

Multi-SP Uses

SP Ramp Time Unit

Standby Sequence
Reset

Auxiliary Output 1

Open in Alarm

Auxiliary Output 2

Open in Alarm

Auxiliary Output 3

Open in Alarm

HB ON/OFF

Heater Burnout Latch

C

C

Heater Burnout
Hysteresis

ST Stable Range

AT Calculated Gain

α

AT Hysteresis

C

Limit Cycle MV

Amplitude

Input Digital Filter

Additional PV Display

MV Display

Automatic Display
Return Time

Alarm 1 Latch

Alarm 2 Latch

Alarm 3 Latch

Move to Protect
Function Group Time

Input Error Output

Cold Junction
Compensation
Method

MB Command
Logic Switching

PV Change Color

PV Stable Band

Alarm 1 ON Delay

Alarm 2 ON Delay

Alarm 3 ON Delay

Alarm 1 OFF Delay

Alarm 2 OFF Delay

Alarm 3 OFF Delay

Input Shift Type

MV at Stop and Error
Addition

Auto/Manual Select
Addition

HS Alarm Use

HS Alarm Latch

HS Alarm Hysteresis

LBA Detection Time

C

C

LBA Level

LBA Band

Control Output 1
Assignment

Control Output 2
Assignment

Auxiliary Output 1
Assignment

Auxiliary Output 2
Assignment

Auxiliary Output 3
Assignment
(900-TC8 and
900-TC16 only)

Character Select

Soak Time Unit

Alarm SP Selection

Manual MV
Limit Enable

PV Rate of Change

Calculation Period

Automatic Cooling

Coefficient Adjustment

Heater Overcurrent

Use

Heater Overcurrent

Latch

Heater Overcurrent

Hysteresis

Move to Calibration
Function Group

PF Setting
(900-TC8 and
900-TC16 only)

Monitor/Setting Item 1

(900-TC8
and 900-TC16 only)

Monitor/Setting Item 2

Monitor/Setting Item 3

Monitor/Setting Item 4

Monitor/Setting Item 5

"PV/SP" Display
Screen Selection

MV Display Selection

PV Decimal Point
Display

PV Status Display
Function

SV Status Display
Function

Display Refresh
Period

Control Output 1
ON/OFF Count
Monitor

Control Output 2
ON/OFF Count
Monitor

Control Output 1
ON/OFF Count
Alarm Set Value

Control Output 2
ON/OFF Count
Alarm Set Value

ON/OFF Counter
Reset

Advertising