Configuration & Basic Operation

3-3

How Function Groups Are
Configured and Operating
the Keys on the Front Panel

Parameters are divided into control categories, each called a function group.
Each of the items/values that can be configured in these function groups is
called a parameter. The function groups on the Bulletin 900 controller are
divided into the following:

Figure 3.4 — Function Group Configuration

Note

(1) You can return to the operation function group by executing a software reset.

(2) You cannot move to other function groups by operating the keys on the front panel

from the calibration function group. You must turn OFF the power supply.

(3) From the manual control function group, key operations can be used to move to the

operation function group only.

Start in manual mode.

25

100

c

25

100

c

a-m

Power ON

(See
note
3.)

(See
note 1.)

(See
note 2.)

Manual
mode

Press the

Key or the

PF Key for at least 1 s.
(See note 4.)

Press the

Key

for at least 3 s while

a-m

is displayed.

(

a-m

will flash after

1st second.)

Operation

Function Group

Press the

Key for

at least 1 s.

Press the

Key

for at least 1 s.

Input password.

Input password while

amoV

is displayed. (Set

value

169)

Press the

Key less than 1 s.

Press the

Key for at

least 3 s. (Display will flash
after 1st second.)

Control stops.

Press the

Key for less than 1 s.

Press the
+

M

Keys for at
least 3 s.
(Display
will flash
after 1st
second.)

Protect Function Group

Control in progress

Function Group change

Not displayed for some models

Control stopped

Start in automatic mode.

Adjustment

Function Group

(See note 4.)

PF Key
(See note 5.)

PF Key
(See note 5.)

Initial Setting
Function Group

Manual Control

Function Group

Monitor/Setting

Item Function Group

Advanced Function

Setting Function Group

Calibration
Function Group

Press the PF Key
for at least 1 s.

Communica-
tions Setting

Function Group

Press the
+

M

Keys for at
least 1 s.

Note The time taken to move

to the protect function group can
be adjusted by chang-
ing the "Move to pro-
tect function group time" setting.

(4) When the PF Setting is configured to A-M in models with a PF Key (900-TC8)

(5) When the PF Setting is configured to PFDP in models with a PF Key (900-TC8)

O

O

O

O

O

O

O

O

O

Advertising