Sub2 – Rockwell Automation 900-TC32 Digital Temperature Controllers, Series B User Manual

Page 322

Advertising
background image

Publication 900-UM007D-EN-E - January 2011

5-94

Parameter Functions & Definitions

Related Parameter

• Program Pattern (Initial Setting function group, page 5-57)

Auxiliary Output 2 Assignment
(900-TC8, 900-TC16)

Conditions of Use:

Auxiliary Output 2 must be assigned.

Function:

This parameter allows you to configure the function assigned to

Auxiliary Output 2.

Table 5.DM

Auxiliary Output 1 Function

Default

none:

No function is assigned to auxiliary output 1

alm1 ➌

o:

Heating Control Output is output

c-o:

Cooling Control Output is output

➊➍

alm1:

Alarm 1is output

alm2:

Alarm 2 is output

alm3:

Alarm 3 is output (900-TC8 only)

p.end:

Program end is output

ralm:

Control output ON/OFF count alarm

➊ If c-o is assigned for standard control, a value equivalent to 0% will be output.

➋ Can be selected only when the program pattern is not set to OFF, but the function is disabled.

➌ If a setting is changed when the Program Pattern parameter is not set to OFF, control automatically switches to

p.end.

➍ If the Standard or Heating/Cooling parameter is set to heating/cooling control, this parameter will automatically

be set to

c-6 (900-TC32).