Pvrp csca, Pv rate of change calculation period, Automatic cooling coefficient adjustment – Rockwell Automation 900-TC32 Digital Temperature Controllers, Series B User Manual

Page 326

Advertising
background image

Publication 900-UM007D-EN-E - January 2011

5-98

Parameter Functions & Definitions

Function:

This parameter allows you to configure whether the MV Upper

Limit and MV Lower Limit parameters are to be enabled when in manual
mode.

Related Parameter

• MV upper limit, MV lower limit (Adjustment Level function group,

page 5-42)

PV Rate of Change Calculation Period

Conditions of Use:

Alarms 1, 2, and 3 must be assigned. The alarm type must

be set to 13.

Function:

The change width (rate of change) can be found for PV input

values in any set time period. Differences with previous values in each set
period are calculated, and an alarm is output if the results exceed the alarm
value.

The PV rate of change calculation period can be set in units of 250 ms
(sampling period).

Related Parameter

• Present value, Process value/set point (Operation function group, page

5-8) Alarm 1 to 3 type (Initial Setting function group, page 5-16)

Automatic Cooling Coefficient Adjustment

Conditions of Use:

The control must be set to heating/cooling control and

2-PID control.

Table 5.DR

Selections

Default

on: Enabled, off: Disabled

off

Table 5.DS

Configurable Range

Units

Default

1 to 999

Sampling period

4 (1 s)

pvrp

csca