Setup Function Group
Diagrams

This diagram shows all of the function groups. To move to the advanced
setting function group and calibration function group, you must enter
passwords. Some parameters are not displayed depending on the protect
function group configuration and the conditions of use.

Figure B.1 — All Function Groups

➊ You can return to the operation level by executing a software reset. When the PF Setting parameter is

crossovered to A-M for a Controller with a PF Key (900-TC8)

➋ It is not possible to move to other levels from the calibration level by operating the keys on the front

panel. It can be done only by first turning OFF the power. When the PF Setting parameter is configured to PFDP
for a Controller with a PF Key (900-TC8).

➌ From the manual control level, key operations can be used to move to the operation level only.

➍ When the PF Setting parameter is confingured to A-M for a Controller with a PF Key (900-TC8 only).

➎ When the PF Setting parameter is configured to PFDP for a Controller with a PF Key (900-TC8 only) From the

manual control function group, key operations can be used to move to the operation function group only.

Start in Manual Mode

25

100

c

25

100

c

a-m

Power ON

O

O

a-m

a-m

O

O

Input Password

amoV

O

O

Control Stops

O

O

M

Protect

Function Group

Control in Progress

Function Group Change

Not Displayed for Some Models

Control Stopped

Start in Automatic Mode

PF Key

O

M

Operation

Function Group

Adjustment

Function Group

Manual Control

Function Group

Manual

Mode

1

3

3

1

4

2

2

5

5

4

Press the Key or the
PF Key for at least 1 second.

Press the
Key for less than 1 second.

Monitor/Setting

Function Group

Press the PF Key
for at least 1 second.

Press the

Key for at

least 1 second.

Press the

Key for at

least 1 second.

Input the password
while is displayed.
(Set Value - 169)

Press the
Key for less than 1 second.

2

Press the Key for at
least 3 seconds.
(Display will flash after 1

st

second.)

Note: The time taken to move
to the Protect level can
be adjusted by changing
the “Move to protect level
time” setting.

Communications

Setting

Function Group

Initial Setting

Function Group

Advanced Setting

Function Group

Calibration

Function Group

Protect the
+ Keys
for at least
1 second.

Protect the
+ Keys
for at least
3 seconds.
(Display will
flash after 1st
second.)

Press the Key for at
least 3 seconds while
is displayed. ( will
flash after 1

st

second.)

Advertising