Publication 900-UM007D-EN-E - January 2011

5-76

Parameter Functions & Definitions

used when the Self-Tuning (ST) parameter is set to OFF (refer to Table 5.CL
and Table 5.CL).

Note:

Analog inputs do not apply to ST Stable Range because units are

°

C or

°

F.

Related Parameters

• PID ON/OFF (Initial Setting function group, page 5-55)
• Input Type (Initial Setting function group, page 5-50)
• ST (Initial Setting function group, page 5-56)

α

Conditions of Use:

Control must be configured for 2-PID control method,

and the ST parameter must be set to OFF.

Function:

This parameter allows you to configure the 2-PID constant for

alpha (

α). Normally, use this parameter at its default.

Related Parameters

• PID ON/OFF (Initial Setting function group, page 5-55)
• ST (Initial Setting function group, page 5-56)

Table 5.CL — Self-Tuning Stable Range

Configurable Range

Units

Default Value

0.1…999.9

°C or °F

15.0

Table 5.CM — Alpha

Configurable Range

Units

Default Value

0.00…1.00

None

0.65