6  RLC Swept SA Measurement Front-Panel & SCPI Reference

Sweep/Control

TV

Pressing this key, when it is not selected, selects the TV input signal as the trigger. A new
sweep/measurement will start synchronized with the next occurrence of the synchronizing pulse
of the selected TV line number.

Pressing this key, when it is already selected, opens a menu of TV Trigger setup functions.  The
default active function in this menu is the TV line number on which you want to trigger.

The Frame and Field options enable you to determine how the fields of the TV picture signal will
be affected by the trigger system. One complete TV image consists of one frame of 525 or 625
horizontal lines depending on the TV standard being used. Each frame is composed of two fields
of interlacing lines, each consisting of 262 1/2 lines (or 312 1/2 lines). The fields are called Field
One and Field Two. Field One is viewed as having 263 lines (or 313 lines) and Field Two is
viewed as having 262 lines (or 312 lines).

For the 525 line NTSC video standard, we refer to TV lines as follows (these are the Field Modes):

Entire Frame, lines 1 to 525

Field One, lines 1 to 263

Field Two, lines 1 to 262 (note that this really refers to "actual" lines 264 to 525)

For the 625 line PAL and SECAM video standards, we refer to TV lines as follows:

Entire Frame, lines 1 to 625

Field One, lines 1 to 313

Field Two, lines 314 to 625

As the Field is changed, the appropriate value for Line is chosen to keep triggering on the same
line as before, or if this is not possible, the corresponding line in the new Field. For example,
suppose line 264 is selected while in the NTSC-M standard and the Entire Frame mode. This is
the first line in Field Two. If Field Two is then selected, the Line number changes to Line 1, the
same actual line in the TV signal. If Field One is then selected, the line number stays at 1, but
now we are triggering in the first line in Field One. The only exception to this is if we are on the
last line of Field One and change to Field Two. In this case, we go to the last line in Field Two.

Key Path

Trigger

Example

TRIG:SOUR TV                 Swept SA measurement

TRIG:<meas>:SOUR TV   Measurements other than Swept SA

Dependencies

This key only appears in Modes which support TV Trigger, otherwise the key is blanked.  If the

Remote Language Compatibility Measurement Application Reference