6  RLC Swept SA Measurement Front-Panel & SCPI Reference
Marker Function

Each detector is then read in successive single-point zero span sweeps, using a sweep time

equal to the specified dwell time.  The value displayed by Measure at Marker represents the
maximum value output by the detector during the dwell timeAutocoupled bandwidth and
average type settings are used for each detector unless the BW & Avg Type key is set to As Set, in
which case the current bandwidth and average type settings are used. 

Each result is then displayed in the measure at marker window as it becomes available. 

The analyzer returns to its pre-Measure at Marker span and settings after executing a Measure

at Marker function, including Bandwidth, Avg Type, and EMC Std - regardless of the setting of
BW & Avg Type

.

Finally, if the sweep had to be aborted, the aborted sweep is restarted.

While the function is executing, all the fields except Freq show “---“ for their values until the
measurement is complete for that detector.   As each detector is read, an informational message is
displayed in the status line, for example:

Measuring with detector 1 (Peak) with RBW=120 kHz

After the last detector, the status line is cleared. 

Meas at Marker Window

This key opens a menu which controls the Measure at Marker window. 

Key Path

Marker Function, Measure at Marker

Readback

In square brackets, the state of the window then the window position, separated by commas, as
[On, Left]

Initial S/W Revision

A.02.00

Window

This key turns the Measure at Marker window on and off.  It turns on automatically when
Measure at Marker is initiated and turns off on a Preset.  If the Window is turned on without a
Measure at Marker result, “---“ is displayed for each result for which the detector is not “Off”.

Key Path

Marker Function, Measure at Marker, Meas at Marker Window

Remote Command

:DISPlay:WINDow:MAMarker[:STATe] ON|OFF|1|0

:DISPlay:WINDow:MAMarker[:STATe]?

Example

:DISP:WIND:MAM ON

Couplings

The window turns on automatically when Measure at Marker is initiated and turns off on a
Preset.