5  Legacy Command Descriptions

CR (Couple Resolution Bandwidth)

CR (Couple Resolution Bandwidth)

Syntax

Legacy Products

8560 series, 8566A/B, 8568A/B

Description

Couples the resolution bandwidth to the span.

The counterpart to the CR command is the command

"RB (Resolution Bandwidth)" on page 442

which breaks the coupling. Use the CR command to re-establish coupling after executing an RB
command.

Format

CR

Query Data Type

N/A

SCPI Equivalent Commands

[:SENse]:BANDwidth[:RESolution]:AUTO ON (see

"Res BW " on page 549

)

Preset

ON

Notes

CR

uses the legacy instrument settings for resolution bandwidth only if Mode Setup >

Preferences> Limit RBW/VBW is set to ON.

Remote Language Compatibility Measurement Application Reference