Legacy products, Description – Agilent Technologies Signal Analyzer N9030a User Manual

Page 465

Advertising
background image

5  Legacy Command Descriptions

SP (Frequency Span)

Legacy Products

8560 series, 8566A/B, 8568A/B

Description

Changes the total displayed frequency range symmetrically about the center frequency.

Format

SP <real>HZ|KHZ|MHZ|GHZ|KZ|MZ|GZ

SP UP|DN

Step Increment: 1, 2, 5, 10 sequence (up to the stop frequency of the instrument)

SP FULL|ZERO|LAST (8560 series only)

SP OA

SP?

Query Data Type

<real> in Hz

SCPI Equivalent Commands

[:SENSe]:FREQuency:SPAN <freq>

[:SENSe]:FREQuency:SPAN?

[:SENSe]:FREQuency:SPAN:PREVious

(See

"Last Span " on page 1148

)

Preset

856x: Full Span

8566: 20 GHz

Remote Language Compatibility Measurement Application Reference

465

Advertising