Agilent Technologies Signal Analyzer N9030a User Manual

Page 1230

Advertising
background image

6  RLC Swept SA Measurement Front-Panel & SCPI Reference
Sweep/Control

Maximum line is 313 for formats PAL-B, D, G, H, I, PAL-N, PAL-N Combin, and SECAM-L.

Readback

Field 1

Initial S/W Revision

Prior to A.02.00

Field Two

When you select Field Two it causes the selected line number to be viewed as an offset into the
second field. If Line 1 is selected, it is the 264th line of the frame (NTSC-M, NTSC-Japan, NTSC–
4.43, PAL-M, PAL–60) or the 314th line of the frame (PAL-B,D,G,H,I, PAL-N, PAL-N-Combin,
SECAM-L).

Key Path

Trigger, TV, Field

Example

TRIG:TV:FMOD EVEN

Min

Field 2 (EVEN)

The minimum line is 1

Max

Field 2 (EVEN)

The maximum line 262 for formats NTSC-M, NTSC-Japan, NTSC–4.43, PAL-M and PAL–60

The maximum line is 312 for formats PAL-B, D, G, H, I, PAL-N, PAL-N Combin, and SECAM-L

Readback

Field 2

Initial S/W Revision

Prior to A.02.00

Standard

Accesses the Standard menu keys which select from the following TV standards: NTSC-M, NTSC-
Japan
, NTSC–4.43, PAL-M, PAL-B,D,G,H,I , PAL-N, PAL-N-Combin, PAL–60, SECAM-L.

As the TV standard is changed, the current line value is clipped as necessary to keep it valid for
the chosen standard and field mode. For example, line 600 is selected in Entire Frame mode in
PAL-N; if NTSC-M is selected, the line number is clipped to 525. Or, if line 313 is selected in Field
1 mode in PAL-N and NTSC-M is selected, the line number is clipped to 263. Changing back to the
PAL-N standard will leave the line number at 263.

Key Path

Trigger, TV

Remote Command

:TRIGger[:SEQuence]:TV:STANdard MNTSc | JNTSc | NTSC443 | MPAL | BPAL |
NPAL | CPAL | PAL60 | LSEC

:TRIGger[:SEQuence]:TV:STANdard?

Example

TRIG:TV:STAN MPAL

TRIG:TV:STAN?

1230

Remote Language Compatibility Measurement Application Reference

Advertising