Agilent Technologies Signal Analyzer N9030a User Manual

Page 168

Advertising
background image

3  Programming the Analyzer
STATus Subsystem

register.

Preset

32767

Min

0

Max

32767

Status
Bits/OPC
dependencies

Sequential command

Initial S/W
Revision

Prior to A.02.00

Questionable Power Register

The following commands and queries are available for this register:

"Questionable Power Condition" on page 168

"Questionable Power Enable" on page 169

"Questionable Power Event Query" on page 169

"Questionable Power Negative Transition" on page 170

"Questionable Power Positive Transition" on page 170

Questionable Power Condition

This query returns the decimal value of the sum of the bits in the Questionable Power Condition
register.

The data in this register is continuously updated and reflects the current conditions.

Mode

All

Remote Command

:STATus:QUEStionable:POWer:CONDition?

Example

STAT:QUES:POW:COND?

Preset

0

Status Bits/OPC dependencies

Sequential command

Initial S/W Revision

Prior to A.02.00