6  RLC Swept SA Measurement Front-Panel & SCPI Reference
Meas Setup

<ampl>Amplitude values units default to dBm. Up to two amplitude values can be provided for
each x-axis value, by repeating <x-axis> in the data list.

Range: –1000 dBm to +1000 dBm

<connect> connect values are either "0" or "1." A "1" means this point will be connected to the
previously defined point to define the limit line. A "0" means that it is a point of discontinuity
and is not connected to the preceding point. The connect value is ignored for the first point.

Remote Command

:CALCulate:LLINe[1]|2|...6:DATA <x>,<ampl>,<connect>{,<x>,<ampl>,
<connect>}

:CALCulate:LLINe[1]|2|...6:DATA?

Example

:CALC:LLIN3:DATA
1E9, –20, 0, 2E9, –20, 1, 2E9, –10, 1, 3E9, –10, 1

describes a stair-stepped limit line.

Preset

Limit line data is cleared by Restore Mode Defaults.  However, it survives shutdown/restart of
the analyzer application (including power cycle)

State Saved

Saved in instrument state

Backwards Compatibility
Notes

In the past it was possible to query the limit trace as though it were a normal trace.  The query of
the limit trace is not supported in the X-series.

Initial S/W Revision

A.02.00

Merge Limit Line Data (Remote Command Only)

Adds the points with the specified values to the current limit line, allowing you to merge limit line
data. Up to two amplitude values are allowed for each X value. If more than 200 points are
entered to be merged, the first 200 points are merged, then an error message ‘too many DATA
entries’ is reported.

Remote Command

:CALCulate:LLINe[1]|2|...6:DATA:MERGe <x-axis>,<ampl>,<connected>{,<x-
axis>,<ampl>,<connected>}

Example

:CALC:LLIN1:DATA:MERG 1000000000, –20, 0, 2000000000, –30, 1

merges the 10GHz segment and the 20GHz segment into limit line 1. Note that the 20GHz
segment will be connected to the next lower point, which may or may not be the 10GHz point.

Notes

This SCPI command is supported for Backwards Compatibility.

Although PSA had a limit of 200 points, it is acceptable to increase that limit.

Preset

Fixed