5

Motor control & motor settings

5.10

Synchronous motor (SM): Pole position identification

104

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Optional settings (starting performance)
Optionally, a PLI without motion can be activated after switching on the i700 servo inverter.

0x2C63 | 0x3463 - pole position identification PLI (without movement)

Danger!

Each pole position identification causes an update of the pole position set in the device!

Therefore, ensure that the response to open circuit in the feedback system is set to Lenze

setting "1: Fault" in

0x2C45

(or

0x3445

for axis B)!

Otherwise, the status of the feedback system in case of open circuit is undefined and the

pole position can assume any values. There is a danger that the machine accelerates in

an uncontrolled way after pole position identification!

Note!

The process of the pole position identification only lasts some milliseconds. During the

pole position identification, the device status does not change. Only after the pole

position identification, the "

Switched on

" device status changes to the "

Operation

enabled

" device status.

From version 01.05

Sub.

Name

Lenze setting

Data type

1

Behaviour after switch-on

0: No operation

UNSIGNED_8

Subindex 1:

Behaviour after switch-on

Starting performance (without or with PLI before starting) in case of synchronous motor (SM) servo control

• In case of all other control modes, the setting has no influence.

Selection list

(Lenze setting printed in bold)

Info

0 No Operation

In the Lenze setting, the behaviour is the same as before.

1 PPI at initial switch-on and after encoder error

only

After the first controller enable and after each encoder

wire breakage, a PLI without movement takes place.

Note:

In order that the PLI is executed after each encoder open

circuit, the response to open circuit in the feedback

system has to be set to the Lenze setting "1: Fault" in

0x2C45

(or

0x3445

for axis B). Otherwise, the status of

the feedback system in case of open circuit is undefined

and the pole position can assume any values. There is a

danger that the machine accelerates in an uncontrolled

way after pole position identification!

2 PPI after every switch-on

After every controller enable, a PLI without movement is

carried out in advance.

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8