8 optimising pull-out slip limitation, 9 display parameter, 0x2b0b | 0x330b - vfc: setpoint frequency – Lenze i700 User Manual

Page 148: Optimising pull-out slip limitation, Display parameter, 0x2b0b, 0x330b, 0x2b0c, 0x330c, For ax

Advertising
background image

5

Motor control & motor settings

5.14

Parameterising the V/f characteristic control

148

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.14.8

Optimising pull-out slip limitation

The following object serves to adapt the pull-out slip function or the maximally permissible current

in the field weakening range.

• If the motor is to be stalled in the field weakening range, the override point can be offset by

reducing the value so that a motor stalling can be prevented.

• If the motor cannot provide enough torque in the field weakening range, the value has to be

increased.

0x2B0C | 0x330C - VFC: Override point of field weakening

5.14.9

Display parameter

0x2B0B | 0x330B - VFC: Setpoint frequency

Subindex 4:

VFC: Oscillation damping - final ramp frequency

Ramp end frequency from which the gain factor is to have reached its rated value.

• By setting a ramp end frequency, a possible negative impact of the oscillation damping on the concentricity

factor in the lower speed range can be reduced.

• The ramp end frequency refers to the rated motor frequency in percent.

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 0 %

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

From version 01.03

Offset of the override point for field weakening

Setting range

(min. value | unit | max. value)

Lenze setting

-500.0

Hz

500.0 0.0 Hz

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

Display area

(min. value | unit | max. value)

Initialisation

-600.0

Hz

600.0 0.0 Hz

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16