11 appendix, 1 table of attributes, Appendix – Lenze i700 User Manual

Page 289

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

289

11

Appendix

11.1

Table of attributes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11

Appendix

11.1

Table of attributes

The table of attributes contains information required for a communication with the controller via

objects.

How to read the table of attributes:

Column

Entry

Meaning

Index

0xXXXX

Object index

Name

Text

Object/parameter name

Subindex: text

Number and parameter name of the subindex

Data type

Data type of the parameter:

INTEGER_8 1 byte, with sign

INTEGER_16 2 bytes with sign
INTEGER_32 4 bytes with sign

UNSIGNED_8 1 byte without sign

UNSIGNED_16 2 bytes without sign
UNSIGNED_32 4 bytes without sign
UNSIGNED_64 8 bytes without sign

STRING(xx) ASCII string (with character length xx)

ARRAY [] OF... ARRAY

Scaling

Scaling of the parameter

Attributes

P Parameter can be persisted.

OSC Parameter can be recorded by means of the oscilloscope function.

Tx Parameter can be mapped into the TPDO.
Rx Parameter can be mapped into the RPDO.

CINH Parameter can only be written to if controller inhibit is set.

Index

Name

Data type

Scaling

Attributes

Communication Area

0x1000

Device: Type

UNSIGNED_32

-

0x1001

Error memory

UNSIGNED_8

-

Tx

0x1008

ECAT: Manufacturer device name

STRING(50)

-

0x1009

Device: Hardware version

STRING(50)

-

0x100A

Device: Software version

STRING(50)

-

0x1018

ECAT: Identity object
1: ECAT: Manufacturer ID

UNSIGNED_32

-

2: ECAT: Product code

UNSIGNED_32

-

3: ECAT: ESI revision

UNSIGNED_32

-

4: ECAT: Serial number

UNSIGNED_32

-

0x10F1

ECAT: Behaviour in case of error
1: Internal device response

UNSIGNED_32

-

2: Synchronisation: Error threshold

UNSIGNED_32

-

P

Greyed out = read only

Advertising