11 appendix, 1 table of attributes – Lenze i700 User Manual

Page 299

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

299

11

Appendix

11.1

Table of attributes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x3035

Manual test mode: Settings
1: Manual test mode: Setpoint current

INTEGER_16

-

OSC

Rx

2: Manual test mode: Frequency

INTEGER_16

1/10

OSC

Rx

3: Manual test mode: Starting angle

INTEGER_16

1/10

0x3036

Manual jog: Settings
1: Manual jog: Setpoint current

UNSIGNED_16

-

Rx

2: Manual jog: Frequency

INTEGER_16

1/10

OSC

Rx

3: Manual jog: Ramp time - current

UNSIGNED_16

-

P

4: Manual jog: Ramp time - frequency

UNSIGNED_16

-

P

5: Manual jog: Time monitoring

UNSIGNED_32

-

P

6: Manual jog: Current controller gain

UNSIGNED_32

1/100

P

7: Manual jog: Current controller reset time

UNSIGNED_32

1/100

P

Axis B - error management

0x3040

Delay time: Reset error

INTEGER_32

-

0x3041

Reset error

UNSIGNED_8

-

0x304F

Current fault

ARRAY [0..63] OF

BYTE

-

Axis B - controller settings

0x3100

Speed controller: Parameter
1: Speed controller: Gain

UNSIGNED_32

1/100000

P

2: Speed controller: Reset time

UNSIGNED_16

1/10

P

3: Speed controller: Rate time

UNSIGNED_16

1/100

P

0x3101

Speed controller: Gain - adaption

UNSIGNED_16

1/100

P

OSC

Rx

0x3102

Speed controller: Load value

INTEGER_16

1/10

P

OSC

Rx

0x3103

Speed: Speed setpoint - filter time

UNSIGNED_16

1/10

P

0x3104

Speed: Actual speed - filter time

UNSIGNED_16

1/10

P

0x3110

Moments of inertia
1: Moment of inertia: Motor

UNSIGNED_32

1/100

P

2: Moment of inertia: Load

UNSIGNED_32

1/100

P

3: Moment of inertia: Motor-load coupling

UNSIGNED_8

-

P

0x3139

Switching frequency

UNSIGNED_8

-

P

0x3141

Current controller: Feedforward control

UNSIGNED_8

-

P

0x3142

Current controller: Parameter
1: Current controller: Gain

UNSIGNED_32

1/100

P

2: Current controller: Reset time

UNSIGNED_32

1/100

P

0x3143

Motor: Current setpoint - filter time

UNSIGNED_16

1/100

P

0x3144

Torque: Notch filter torque setpoint
1: Notch filter 1: Frequency

UNSIGNED_16

1/10

P

2: Notch filter 1: Bandwidth

UNSIGNED_16

1/10

P

3: Notch filter 1: Damping

UNSIGNED_8

-

P

4: Notch filter 2: Frequency

UNSIGNED_16

1/10

P

5: Notch filter 2: Bandwidth

UNSIGNED_16

1/10

P

6: Notch filter 2: Damping

UNSIGNED_8

-

P

0x3145

Torque: Jerk limitation setpoint

UNSIGNED_16

1/10

P

0x3146

Cyclic sync torque mode: Speed limitation
1: Speed limitation: Upper speed limit

INTEGER_32

480000/2

31

P

OSC

Rx

2: Speed limitation: Lower speed limit

INTEGER_32

480000/2

31

P

OSC

Rx

Index

Name

Data type

Scaling

Attributes

Greyed out = read only

Advertising