CiA402 device profile

7.3

General CiA402 parameters

166

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.3

General CiA402 parameters

This chapter describes the general CiA402 parameters.
All objects correspond to the CiA402 specification, but some of them have only a restricted value

range.

Objects described in this chapter:

Objects described in other chapters:

0x60FD | 0x68FD - Digital inputs

Related topics:

Touch probe (TP)

Delay times of the digital inputs and required minimum signal lengths

Object

Name

Data type

Axis A

Axis B

0x60FD

0x68FD

Digital inputs

UNSIGNED_32

0x6404

0x6C04

Motor manufacturer

STRING(50)

0x6502

0x6D02

Supported drive modes

UNSIGNED_32

0x67FF

0x6FFF

ECAT: Device Profile Number

UNSIGNED_32

Greyed out = read access only

Object

Name

Data type

Axis A

Axis B

0x603F

0x683F

Error code

UNSIGNED_16

Greyed out = read access only

Display of the current status of the digital inputs

Display area

(min. value | unit | max. value)

Initialisation

0

4294967295 0

Value is bit-coded:

Info

Bits 0-3 Not specified

Bits 4-15 Reserved

Bit 16 Level at digital input 1

0: LOW level

1: HIGH level

Bit 17 Level at digital input 2

0: LOW level

1: HIGH level

Bits 18-31 Reserved

Write access  CINH  OSC  P  RX  TX

UNSIGNED_32