Error code 0x7380: hiperface communication error, Error code 0x8181: ethercat communication, Error code 0x8280: sync manager - address [value – Lenze i700 User Manual

Page 272: 9diagnostics & error management

Advertising
background image

9

Diagnostics & error management

9.4

CiA402 error codes / error messages

272

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Error code 0x7380: Hiperface communication error

Text ID: 0x3A

Error code 0x7381: Hiperface: Invalid absolute value - motor speed too high

Text ID: 0x41

Error code 0x8180: ECAT DC - synchronisation required

Text ID: 0x15

Error code 0x8181: EtherCAT communication

Text ID: 0x19

Error code 0x8280: Sync Manager - address [value]

Text ID: 0x16

Cause

Remedies

Response

Communication with HIPERFACE®

absolute value encoder is disturbed.

• Check the supply voltage of the

encoder (

0x2C42:2

|

0x3442:2

).

• Check wiring to the encoder.

Up to and including version 01.05:

Fault

(adjustable in

0x2C41:4

|

0x3441:4

)

From version 01.06:

Class II fault

(adjustable in

0x2C41:4

|

0x3441:4

)

• If "fault" is set, the response set in

0x605E

|

0x685E

takes place.

Cause

Remedies

Response

The absolute position of the

HIPERFACE® absolute value encoder

cannot be accepted as the motor

rotates too fast.

Let the motor coast.

Fault

(adjustable in

0x2C41:4

|

0x3441:4

)

Cause

Remedies

Response

EtherCAT DC mode not activated.

(DC = Distributed Clock)

Activate DC mode.

Warning

Cause

Remedies

Response

EtherCAT communication error

• Check EtherCAT bus cabling.

• Select a longer PDI watchdog

time.

Class II fault

• The response set in

0x605E

|

0x685E

takes place.

Cause

Remedies

Response

Incorrect Sync Manager setting of the

EtherCAT master.

• Check the devices on the bus.

• Check cabling or sequence of the

devices on the bus.

• Remove the i700 servo inverter

from the project tree and rescan

the bus.

• Check the device description of

the i700 servo inverter.

Fault