Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

181

7

CiA402 device profile

7.4

Device control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.2.1

Not ready to switch on

This is the status of the controller directly after

switching on the supply voltage.

• In this device status, the device is

initialised.

• Communication is not possible yet.
• The controller cannot be parameterised

yet and no device commands can be

carried out yet.

• The motor brake, if available, is closed.
• The operation is inhibited.

Bit pattern for the "Not ready to switch on" device status in the Statusword (

0x6041

or

0x6841

for axis B):

Bits 15 - 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Warning is

active

Switch on

disabled

Quick stop

Voltage

enabled

Fault active

Operation

enabled

Switched on

Ready to

switch on

X

X

0

X

X

0

0

0

0

Note!

The controller changes to "

Switch on disabled

" if the EtherCAT bus is in the "Operational"

status, or PDO communication is deactivated via object

0x2824

(or

0x3024

for axis B).

Ready to

switch on

Not ready to

switch on

Switched

on

Operation

enabled

Fault reaction

active

Fault

active

Switch on

disabled

Quick stop

active

Power on