Motor control & motor settings

52

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5

Motor control & motor settings

This chapter describes the commissioning of the motor control in a recommended sequence.

Objects described in this chapter

Object

Name

Data type

Axis A

Axis B

Axis control

0x2822

0x3022

Axis command

UNSIGNED_32

0x2823

0x3023

Axis command: Progress

UNSIGNED_8

0x2825

0x3025

Modes of operation

UNSIGNED_8

0x2832

0x3032

Identification: Status word

UNSIGNED_16

0x2835

0x3035

Manual test mode: Settings

RECORD

0x2836

0x3036

Manual jog: Settings

RECORD

Controller settings

0x2900

0x3100

Speed controller: Parameter

RECORD

0x2901

0x3101

Speed controller: Gain - adaption

UNSIGNED_16

0x2902

0x3102

Speed controller: Load value

INTEGER_16

0x2903

0x3103

Speed: Speed setpoint - filter time

UNSIGNED_16

0x2904

0x3104

Speed: Actual speed - filter time

UNSIGNED_16

0x2910

0x3110

Moments of inertia

RECORD

0x2939

0x3139

Switching frequency

UNSIGNED_8

0x2941

0x3141

Current controller: Feedforward control

UNSIGNED_8

0x2942

0x3142

Current controller: Parameter

RECORD

0x2943

0x3143

Motor: Current setpoint - filter time

UNSIGNED_16

0x2944

0x3144

Torque: Notch filter torque setpoint

RECORD

0x2945

0x3145

Torque: Jerk limitation setpoint

UNSIGNED_16

0x2947

0x3147

Inverter characteristic: Voltage grid points (y)

RECORD

0x2980

0x3180

Position controller: Gain

UNSIGNED_32

0x2981

0x3181

Position controller: Gain - adaption

UNSIGNED_16

0x2982

0x3182

Position controller: Output signal limitation

UNSIGNED_32

0x2983

0x3183

Position: Select new actual position

INTEGER_32

0x2984

0x3184

Determine target position: Mode

UNSIGNED_8

0x29C0

0x31C0

Field controller: Parameter

RECORD

0x29E0

0x31E0

Field weakening controller: Parameter

RECORD

0x29E1

0x31E1

Field set value limitation

UNSIGNED_16

0x29E2

0x31E2

DC link circuit voltage: Filter time

UNSIGNED_16

0x29E3

0x31E3

Motor voltage act. value: Filter time

UNSIGNED_16

0x29E4

0x31E4

Voltage reserve range

UNSIGNED_8

V/f operation

0x2B00

0x3300

VFC: V/f characteristic - shape

UNSIGNED_8

0x2B01

0x3301

VFC: V/f characteristic - define reference point

RECORD

0x2B02

0x3302

VFC: User-definable V/f characteristic - frequency grid points (x)

RECORD

0x2B03

0x3303

VFC: User-definable V/f characteristic - voltage grid points (y)

RECORD

0x2B04

0x3304

VFC: Voltage vector control - current setpoint

UNSIGNED_32