3 history buffer, 0x10f3 - diagnostics: history buffer, History buffer – Lenze i700 User Manual

Page 265: 0x10f3, E history buffer, In the, 9diagnostics & error management

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

265

9

Diagnostics & error management

9.3

History buffer

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.3

History buffer

Via the history buffer (

0x10F3

), the controller can access the last 32 messages of the i700 servo

inverter.

• The history buffer is saved persistently to the i700 servo inverter.
• The structure of the history buffer corresponds to a ring buffer:

• As long as there is free history buffer space available, a message is placed in the next free slot

in the buffer.

• If all buffer slots are full, the oldest message is deleted for a new one.
• The latest messages will always remain available.

• See the "Diag code" (32-bit word) of every single message to find out which axis the message

refers to:

CiA402 error codes / error messages

( 267)

0x10F3 - Diagnostics: History buffer

Diag code bits 0 ... 15

Diag code bits 16 ... 31

0xE000  device error/warning

CiA402 error code (device-specific)

0xE001  fault/warning axis A

CiA402 error code (axis-specific)

0xE002  fault/warning axis B

CiA402 error code (axis-specific)

Document "ETG.1020 Protocol Enhancements"

See chapter 13.3 of document "ETG.1020 Protocol Enhancements" provided by the

EtherCAT Technology Group (ETG) for detailed information on the structure of the

diagnostic messages.

Sub.

Name

Lenze setting

Data type

1

Max. number of messages

32

UNSIGNED_8

2

Latest message

0

UNSIGNED_8

3

Latest acknowledged message

0

UNSIGNED_8

4

New active message

0

UNSIGNED_8

5

Control bits

0

UNSIGNED_16

Subindex 1:

Max. number of messages

Maximum number of messages which can be stored in the history buffer (from subindex 6).
Display area

(min. value | unit | max. value)

Initialisation

0

255 32

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

Subindex 2:

Latest message

Subindex of the most recent message
Display area

(min. value | unit | max. value)

Initialisation

0

255 0

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

Advertising