0x2942 | 0x3142 - current controller: parameter, 0x2941, 0x3141 – Lenze i700 User Manual

Page 107: 0x2942, 0x3142, 0x2943, 0x3143, E object, 0x2942:1 0x3142:1, 0x2942:2 0x3142:2

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

107

5

Motor control & motor settings

5.11

Setting control loops

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2941 | 0x3141 - Current controller: Feedforward control

0x2942 | 0x3142 - Current controller: Parameter

0x2943 | 0x3143 - Motor: Current setpoint - filter time

Activate/deactivate the current controller feedforward control

• Since the positioning movements are known, they can be precontrolled in order to slightly increase the

achievable dynamic performance of the control loop.

Note!

A successful feedforward control requires knowledge of the equivalent circuit data of the motor. If only estimated

values are available, the feedforward control should not be activated.

Selection list

(Lenze setting printed in bold)

0 Off
1 Activate

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

Sub.

Name

Lenze setting

Data type

1

Current controller: Gain

148.21 V/A

UNSIGNED_32

2

Current controller: Reset time

3.77 ms

UNSIGNED_32

Subindex 1:

Current controller: Gain

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

V/A

750.00 148.21 V/A

Write access  CINH  OSC  P  RX  TX

Scaling: 1/100

UNSIGNED_32

Subindex 2:

Current controller: Reset time

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

ms

2000.00 3.77 ms

Write access  CINH  OSC  P  RX  TX

Scaling: 1/100

UNSIGNED_32

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

ms

10.00 0.00 ms

Write access  CINH  OSC  P  RX  TX

Scaling: 1/100

UNSIGNED_16