0x2de0 | 0x35e0 - advanced settings, 0x2de0, 0x35e0 – Lenze i700 User Manual

Page 73: Loading the standard inverter characteristic, 5motor control & motor settings

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

73

5

Motor control & motor settings

5.7

Compensating for inverter influence on output voltage

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Advanced settings
For characteristic detection, the current controller is parameterised automatically at the beginning

of the identification process. For motors with a very low stator leakage inductance (< 1 mH), an

automatic parameter setting may fail and the actual identification process is aborted with an error

message like e.g. "short circuit".

• For such a case, it is possible to set the current controller manually via the object

0x2942

(or

0x3142

for axis B).

• Whether the current controller is to be selected automatically or the values below

0x2942

(or

0x3142

for axis B) are active, is selected via the object

0x2DE0:1

(or

0x35E0:1

for axis B).

0x2DE0 | 0x35E0 - Advanced settings

Loading the standard inverter characteristic
If an incorrect inverter characteristic has been determined or none at all, it is possible to load a

device-typical standard inverter characteristic.

How to load the standard inverter characteristic:

1. Set object

0x2822

(or

0x3022

for axis B) to "1".

• The progress of the procedure is shown in object

0x2823

(or

0x3023

for axis B).

2. For permanent storage: After completion of the procedure, upload the inverter

characteristic set in

0x2947

(or

0x3147

for axis B) to the controller from the i700 servo

inverter.
The »EASY Starter« serves to save the parameter settings of the i700 servo inverter as

parameter file (*.gdc). In the »PLC Designer«, this file can then be imported in the

corresponding axis.

Saving changed parameters safe against mains failure

( 60)

Sub.

Name

Lenze setting

Data type

1

Current controller: Setting for identification

0: Automatic setting

UNSIGNED_8

2

Sensorless SM: Injection signal during test

mode

0: Off

UNSIGNED_8

Subindex 1:

Current controller: Setting for identification

Selection list

(Lenze setting printed in bold)

0 Automatic setting
1 Manual setting (0x2942/0x3142)

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8

Subindex 2:

Sensorless SM: Injection signal during test mode

Selection list

(Lenze setting printed in bold)

0 Off
1 On

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8