Setting the feedback system for the servo control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.9.4

Additional settings for SinCos absolute value encoders with HIPERFACE® protocol

Absolute value encoders are especially suitable for:

• Synchronous motors operated in the "servo control" mode. The synchronous motor (SM) servo

control requires a pole position angle. This has to be detected only once during commissioning

and saved as offset towards the absolute position in the axis data.

• Positioning modes in which homing is to be carried out only once.

The analog evaluation of the sin/cos tracks causes a high resolution. With regard to the storage of

the position information, we distinguish between singleturn and multiturn encoders:

• Singleturn: Storage within one revolution
• Multiturn: Storage within a number of revolutions

Supported encoder types with HIPERFACE® protocol
The following encoder types are supported by the i700 servo inverter:

Use of a non-supported encoder type
If an encoder is to be used, the type code of which is not listed in the table of the supported encoder

types, this encoder can be introduced to the i700 servo inverter via the subindices 2 and 3 of the

hiperface parameters described in the following. Please also observe the notes in the description of

subindex 8.

Reading data out of the encoder
The "Determine data of the Hiperface encoder" function in the object

0x2822

(or

0x3022

for axis B)

serves to read the type code, number of increments and number of distinguishable revolutions out

of the encoder and automatically enter then into the corresponding Hiperface parameters.

Type

Increments/revolution

Absolute revolutions

Type code

(

0x2C41:1

|

0x3441:1

)

AM1024-8V-H (SRM50)

1024

4096

(Multiturn)

39

AM1024-8V-K2

1024

39

AM16-8V-H (SEL37)

16

71

AM16-8V-H (SEL52)

16

71

AM512-8V-H (SCM70)

512

7

AS1024-8V-H (SRS50)

1024

1

(Singleturn)

34

AS1024-8V-K2

1024

34

AS16-8V-H (SEK37)

16

66

AS16-8V-H (SEK52)

16

66

AS512-8V-H (SCS70)

512

2