5.8.2.1

Enter motor nameplate data

If the equivalent circuit data of the motor required for the motor model are not known, they can

automatically be determined by approximation by the i700 servo inverter by means of the motor

nameplate data before they are set.

How to have the equivalent circuit data determined by the i700 servo inverter:

1. Set the complete motor nameplate data in object

0x2C01

(or

0x3401

for axis).

2. Set the rated motor current in object

0x6075

(or

0x6875

for axis B).

3. Set object

0x2822

(or

0x3022

for axis B) to "3" in order to have the equivalent circuit data

determined by approximation.

• The progress of the procedure is shown in object

0x2823

(or

0x3023

for axis B).

4. For permanent storage: Upload the set equivalent circuit data to the controller from the

i700 servo inverter after the procedure has been completed:

• For asynchronous motor (ASM): Object

0x2C02

(or

0x3402

for axis B).

• For synchronous motor (SM): Object

0x2C03

(or

0x3403

for axis B).

The »EASY Starter« serves to save the parameter settings of the i700 servo inverter as

parameter file (*.gdc). In the »PLC Designer«, this file can then be imported in the

corresponding axis.

Saving changed parameters safe against mains failure

( 60)

5.8.2.2

Set motor parameters manually

If all required motor data are known (e.g. by means of a data sheet provided by the motor

manufacturer), they can be set manually in the following parameters:

Object

Name

Required for

Axis A

Axis B

SM

ASM

0x2C01:1 0x3401:1

Motor: Number of pole pairs

0x2C01:2 0x3401:2

Motor: Stator resistance (value at 20°C)

0x2C01:3 0x3401:3

Motor: Stator leakage inductance

0x2C01:4 0x3401:4

Motor: Rated speed

0x2C01:5 0x3401:5

Motor: Rated frequency

0x2C01:6 0x3401:6

Motor: Rated power

0x2C01:7 0x3401:7

Motor: Rated voltage

0x2C01:8 0x3401:8

Motor: Rated cosine phi

0x2C01:9 0x3401:9

Motor: Insulation class

0x2C02:1 0x3402:1

Motor (ASM): Rotor resistance (value at 20 °C)

0x2C02:2 0x3402:2

Motor (ASM): Mutual inductance

0x2C02:3 0x3402:3

Motor (ASM): Magnetising current

0x2C03:1 0x3403:1

Motor (SM): e.m.f. constant (KELL)

0x2C03:2 0x3403:2

Motor (SM): Pole position

0x2C03:3 0x3403:3

Motor (SM): Temperature coefficient - magnets

0x6075

0x6875

Motor rated current

0x6076

0x6876

Motor rated torque