Diagnostics & error management

9.1

LED status displays

260

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.1

LED status displays

The LED status displays on the front of the i700 servo inverter provide quick information on some

operating states.

• The two LEDs "RDY" and "ERR" serve to indicate the device status.

• Three green LEDs at the EtherCAT interfaces (RJ45 sockets X4 and X5) serve to indicate the

EtherCAT bus status and the connection status of the input and output socket. The arrangement

of the LEDs can be seen from the "Servo-Inverter i700" hardware manual.

LED

Status

Meaning

RDY

Off

24 V supply voltage missing
Single axis: Axis is inhibited

Double axis: Both axes are inhibited
Single axis: Axis is enabled

Double axis: One or both axes are enabled

ERR

Off

No error.
Single axis: Device error or axis error

Double axis: Device error or axis error in one axis or both axes

LED

Status

Meaning

RUN

Off

EtherCAT status "Init"
EtherCAT state "Pre-Operational"

EtherCAT state "Safe-Operational"

EtherCAT state "Operational"

EtherCAT state "Bootstrap"

L/A

Off

No EtherCAT connection
EtherCAT communication active