Error code 0x2384: ultimate motor current reached, 9diagnostics & error management – Lenze i700 User Manual

Page 268

Advertising
background image

9

Diagnostics & error management

9.4

CiA402 error codes / error messages

268

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Error code 0x2380: Fault - utilisation of the power section (Ixt) too high

Text ID: 0x06

Error code 0x2381: Warning - Utilisation of the power section (Ixt) too high

Text ID: 0x07

Error code 0x2382: Fault - device utilisation (Ixt) too high

Text ID: 0x08

Error code 0x2383: Warning - device utilisation (Ixt) too high

Text ID: 0x09

Error code 0x2384: Ultimate motor current reached

Text ID: 0x22

Error code 0x2385: Output current > [value] A (maximum device current)

Text ID: 0x24

Cause

Remedies

Response

Frequent and too long acceleration

processes with overcurrent.

Check drive dimensioning.

Fault

Cause

Remedies

Response

Frequent and too long acceleration

processes with overcurrent.

Check drive dimensioning.

Warning

Cause

Remedies

Response

Frequent and too long acceleration

processes with overcurrent.

Check drive dimensioning.

Fault

Cause

Remedies

Response

Frequent and too long acceleration

processes with overcurrent.

Check drive dimensioning.

Warning

Cause

Remedies

Response

The motor current has exceeded the

"ultimate" motor current.

The "ultimate" motor current

corresponds to the current level at

which the permanent magnets of a

synchronous motor suffer

permanent damage.

Reduce maximum current

(

0x6073

|

0x6873

) and/or adjust the

current controller (

0x2942

|

0x3142

)

in order to reduce the current

overshoot.

Fault

(adjustable in

0x2D46:2

|

0x3546:2

)

• Threshold can be adapted in

0x2D46:1

|

0x3546:1

.

Cause

Remedies

Response

The desired maximum current

(

0x6073

|

0x6873

) is higher than the

maximum current of the axis (display

in

0x2DDF:2

|

0x35DF:2

).

The permissible maximum current

(

0x6073

|

0x6873

) is:

• Setting of rated motor current in

0x6075

|

0x6875

.

Warning

Maximum axis current

Rated motor current

-----------------------------------------------------------

Advertising