0x2836 | 0x3036 - manual jog: settings, 0x2836, 0x3036 – Lenze i700 User Manual
Page 67: 0x2836:1 0x3036:1, 0x2836:3 0x3036:3, 0x2836:2 0x3036:2, 0x2836:4 0x3036:4, 0x2836:5 0x3036:5, 5motor control & motor settings
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
67
5
Motor control & motor settings
5.4
Manual control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Preconditions for the execution
• The motor must be able to rotate freely.
• The controller is free of errors and is in the "
" device status.
Response of the motor during the execution
The motor rotates according to the manual jog commands.
How to activate the manual control:
1. If the controller is enabled, inhibit the controller.
Enable/inhibit operation via control word
2. Set object
(or
for axis B) to "4" to change to the "Manual control" mode.
3. Enable the controller to start the manual control.
• In the »EASY Starter«, the controller can be enabled via the operator dialog for manual
control. The operator dialog also takes priority over the control word (
for axis B).
• The possible settings for the manual control mode are described in the following.
4. To stop the manual control:
• Inhibit controller.
• Set object
(or
for axis B) to "0" to change back to the CiA402 mode.
0x2836 | 0x3036 - Manual jog: Settings
Sub.
Name
Lenze setting
Data type
Manual jog: Current setpoint
30 %
UNSIGNED_16
Manual jog: Frequency
0.0 Hz
INTEGER_16
Manual jog: Ramp time - current
0 ms
UNSIGNED_16
Manual jog: Ramp time - frequency
500 ms
UNSIGNED_16
Manual jog: Time monitoring
2500 ms
UNSIGNED_32
Manual jog: Current controller - gain
20.00 V/A
UNSIGNED_32
Manual jog: Current controller - reset time
20.00 ms
UNSIGNED_32
Subindex 1:
Manual jog: Setpoint current
Selection of the current setpoint for the manual control
• 100 % ≡ rated axis current (
or
for axis B)
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
200 30 %
Write access CINH OSC P RX TX
UNSIGNED_16
Subindex 2:
Manual jog: Frequency
Selection of the frequency for manual control
Setting range
(min. value | unit | max. value)
Lenze setting
-1000.0
Hz
1000.0 0.0 Hz
Write access CINH OSC P RX TX
Scaling: 1/10
INTEGER_16