0x1603 - rpdo-->axis a: velocity mode (vl), 0x1604 - rpdo-->axis a: touch probe (tp), 0x1603 – Lenze i700 User Manual

Page 314: 0x1602, 0x1601, 0x1604, 11 appendix

Advertising
background image

11

Appendix

11.3

Communication objects

314

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x1601 - RPDO-->Axis A: Cyclic sync torque mode (cst)

0x1602 - RPDO-->Axis A: Cyclic sync velocity mode (csv)

0x1603 - RPDO-->Axis A: Velocity mode (vl)

0x1604 - RPDO-->Axis A: Touch probe (TP)

Fixed, preconfigured PDO mapping object for

"Cyclic sync torque mode"

Sub.

Name

Lenze setting

Data type

1 (cst) RPDO-->A: 0x6040 (Controlword)

0x60400010

UNSIGNED_32

2 (cst) RPDO-->A: 0x2830 (Lenze control word)

0x28300010

UNSIGNED_32

3 (cst) RPDO-->A: 0x6060 (Modes of operation)

0x60600008

UNSIGNED_32

4 (cst) RPDO-->A: 0x60B2 (Torque: Offset)

0x60B20010

UNSIGNED_32

5 (cst) RPDO-->A: 0x6071 (Target torque)

0x60710010

UNSIGNED_32

6 (cst) RPDO-->A: 0x2946/1 (upper speed limit)

0x29460120

UNSIGNED_32

7 (cst) RPDO-->A: 0x2946/2 (lower speed limit)

0x29460220

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX

Fixed, preconfigured PDO mapping object for

"Cyclic sync velocity mode"

Sub.

Name

Lenze setting

Data type

1 (csv) RPDO-->A: 0x6040 (Controlword)

0x60400010

UNSIGNED_32

2 (csv) RPDO-->A: 0x2830 (Lenze control word)

0x28300010

UNSIGNED_32

3 (csv) RPDO-->A: 0x6060 (Modes of operation)

0x60600008

UNSIGNED_32

4 (csv) RPDO-->A: 0x60B2 (Torque: Offset)

0x60B20010

UNSIGNED_32

5 (csv) RPDO-->A: 0x60FF (Target velocity)

0x60FF0020

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX

Fixed, preconfigured PDO mapping object for

"Velocity mode"

Sub.

Name

Lenze setting

Data type

1 (vl) RPDO-->A: 0x6040 (Controlword)

0x60400010

UNSIGNED_32

2 (vl) RPDO-->A: 0x2830 (Lenze control word)

0x28300010

UNSIGNED_32

3 (vl) RPDO-->A: 0x6060 (Modes of operation)

0x60600008

UNSIGNED_32

4 (vl) RPDO-->A: 0x6042 (vl target velocity)

0x60420010

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX

Fixed, preconfigured PDO mapping object for

touch probe detection

Sub.

Name

Lenze setting

Data type

1 (TP) RPDO-->A: 0x60B8 (Touch probe function)

0x60B80010

UNSIGNED_32

Write access  CINH  OSC  P  RX  TX