7cia402 device profile – Lenze i700 User Manual

Page 180

Advertising
background image

7

CiA402 device profile

7.4

Device control

180

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Further Lenze-specific status bits (bits 8 ... 15)

Device status

Bit pattern in the status word

Bit 15

Bit 14

Bit 13

Bit 12

Bit 11

Bit 10

Bit 9

Bit 8

STO

is not active

Brake

released

Following

error

Drive follows

setpoint

selection

Internal

limitation is

active

Target

reched

Remote

RPDOs

deactivated

Brake applied

X

0

X

X

X

X

X

X

Brake released

X

1

X

X

X

X

X

X

STO is active

0

X

X

X

X

X

X

X

STO is not active

1

X

X

X

X

X

X

X

X = Status not significant

Note!

If STO is inhibited, a changeover to the "

Switch on disabled

" device status takes place and

a warning is transmitted.