0x2ddc | 0x35dc - slip: actual slip, 0x2ddd | 0x35dd - device: actual output frequency, 0x2ddd – Lenze i700 User Manual

Page 287: 0x35dd, 0x2ddc, 0x35dc, 0x2dde, 0x35de, 10 service/internal

Advertising
background image

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

287

10

Service/internal

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

0x2DDC | 0x35DC - Slip: Actual slip

0x2DDD | 0x35DD - Device: Actual output frequency

0x2DDE | 0x35DE - motor: Actual position of rotor angle

Subindex 3:

Q-current controller: output signal

Display area

(min. value | unit | max. value)

Initialisation

-3276.7

V

3276.7

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

Subindex 4:

D-voltage (magnetisation)

Display area

(min. value | unit | max. value)

Initialisation

-3276.7

V

3276.7

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

Subindex 5:

Q-voltage (torque)

Display area

(min. value | unit | max. value)

Initialisation

-3276.7

V

3276.7

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

Display area

(min. value | unit | max. value)

Initialisation

-3276.7

Hz

3276.7

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

Display area

(min. value | unit | max. value)

Initialisation

-3276.7

Hz

3276.7 0.0 Hz

Write access  CINH  OSC  P  RX  TX

Scaling: 1/10

INTEGER_16

Display area

(min. value | unit | max. value)

Initialisation

0

2047

Write access  CINH  OSC  P  RX  TX

INTEGER_16

Advertising