5motor control & motor settings – Lenze i700 User Manual

Page 94

Advertising
background image

5

Motor control & motor settings

5.9

Setting the feedback system for the servo control

94

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Communication error monitoring
Communication with the encoder is monitored by the protocol and by generating a checksum. If a

violation of the communication protocol or a defect frame is detected, a response occurs as a

function of the device status and the setting in subindex 4 (Hiperface communication error:

Response):

5.9.5

Detection of changed settings of the feedback system

Bit 0 of the Lenze statusword 2 (

0x2833

or

0x3033

for axis B) indicates whether the settings of the

feedback system have been changed during operation. Bit 0 is set to"1" if one of the following

objects have been changed since the last controller inhibit:

After a controller enable, bit 0 of the Lenze status word 2 is always reset to "0".

Device status

Response in the event of an error

(depending on the error responses set in the

Subindex 4

)

0: No Response

1: Trouble

2: Warning

Not ready to switch on

Warning

Switch on disabled

Warning

Ready to switch on

-

Fault

Warning

Switched on

-

Fault

Warning

Operation enabled

-

Fault

Warning

Quick stop is active

-

Fault

Warning

Fault reaction active

-

Warning

Fault

-

Warning

Object

Name

Axis A

Axis B

0x2C40

0x3440

Encoder: Type

0x2C41:2 0x3441:2

Hiperface: User defined - Type code

0x2C41:3 0x3441:3

Hiperface: User defined - Number of revolutions

0x2C41:5 0x3441:5

Hiperface: Serial number

0x2C42:1 0x3442:1

Encoder: Increments / revolution

0x608F

0x688F

Position encoder resolution

Advertising